CelCulture® CO₂ Incubator

Box CO₂ incubators offering rapid temperature and gas recovery, ISO Class 5 cleanliness, ISOCIDE™ antimicrobial coating and an inner door kit to reduce contamination risk. The CelCulture® CO₂ Incubator is designed to replicate the natural environment for developing embryos by maintaining low levels of oxygen.

Animal IVF
Embryo Culture

For Animal IVF & Embryo Culture

Features

Fast temperature and gas recovery

Maximum protection against harmful contaminants

Different capacity models available

Easy chamber calibration and validation

Get a Quote Download Catalogue Watch Video
Product Details Product Features Order Information Literature & Resources

Fast temperature and gas recovery

  • Fast temperature and gas recovery time using sophisticated firmware and optimally located precision sensors to monitor and control temperature, CO2 and O2 levels inside the chamber.
  • Inner Door Kit helps the fast recovery of parameters reduces contamination risk, with each section having a dedicated door panel
Fast temperature and gas recovery
Maximum protection against harmful contaminants

Maximum protection against harmful contaminants

  • 90°C moist heat decontamination cycle
  • ULPA filter cleans the air so that chamber returns to ISO Class 5 cleanliness in 11 minutes upon door closing
  • ISOCIDE™ antimicrobial coating

Different capacity models available

Capacity models to suit different needs: 50 L model with 2 sections; 170 L model with 4 sections; 240 L model with 4 or 6 sections
Different capacity models available

Easy chamber calibration and validation

Access ports provides easy calibration and validation of the chamber parameters

Order Information

CelCulture® CO₂ Incubator
Item Code Model Code Description
IR Sensor Model with Stainless Steel Chamber
2170257 CCL-050B-8-IVF Celculture® Incubator, 50L, IR sensor, CO₂ control, Moist Heat Decon, with Sealed Inner Door Kit for 50L
(2 Glass Doors With Latches), Factory Installed, 230VAC, 50/60 Hz
2170272 CCL-170B-8-IVF CelCulture® Incubator 170L IR Sensor, CO₂ Control ULPA, Moist Heat Decon, with Sealed Inner Door Kit for 170L
(4 Glass Doors With Latches), Factory Installed, 230VAC 50/60Hz
2170278 CCL-240B-8-IVF CelCulture® Incubator 240L IR Sensor CO₂ Control, ULPA, Moist Heat Decon, with Sealed Inner Door Kit for 240L
(4/6 Glass Doors With Latches), Factory Installed, 230VAC 50/60Hz
2170258 CCL-050B-9-IVF Celculture® Incubator, 50L, IR sensor, CO₂ control, Moist Heat Decon, with Sealed Inner Door Kit for 50L
(2 Glass Doors With Latches), Factory Installed, 115VAC, 50/60 Hz
2170273 CCL-170B-9-IVF CelCulture® Incubator 170L IR Sensor, CO₂ Control ULPA, Moist Heat Decon, with Sealed Inner Door Kit for 170L
(4 Glass Doors With Latches), Factory Installed, 115VAC 50/60Hz
2170279 CCL-240B-9-IVF CelCulture® Incubator 240 L, IR Sensor, CO₂ Control, ULPA, Moist Heat Decon, with Sealed Inner Door Kit for 240L
(4/6 Glass Doors With Latches), 115 VAC, 50/60 Hz
Supressed O2 Model with Stainless Steel Chamber
2170260 CCL-050T-8-IVF Celculture® Incubator, 50L, IR sensor, CO₂ & O₂ control, Moist Heat Decon, with Sealed Inner Door Kit for 50L
(2 Glass Doors With Latches), Factory Installed, 230VAC, 50/60 Hz
2170275 CCL-170T-8-IVF CelCulture® Incubator 170L IR Sensor, CO₂ & O₂ Control ULPA, Moist Heat Decon, with Sealed Inner Door Kit for 170L
(4 Glass Doors With Latches), Factory Installed, 230VAC 50/60Hz
2170281 CCL-240T-8-IVF Celculture® Incubator, 240L, IR sensor, CO₂ & O₂ control ULPA, with Sealed Inner Door Kit for 240L
(4/6 Glass Doors With Latches), Factory Installed, 230VAC 50/60Hz
2170261 CCL-050T-9-IVF Celculture® Incubator, 50L, IR sensor, CO₂ & O₂ control, Moist Heat Decon, with Sealed Inner Door Kit for 50L
(2 Glass Doors With Latches), Factory Installed, 115VAC, 50/60 Hz
2170276 CCL-170T-9-IVF CelCulture® Incubator 170L IR Sensor, CO₂ & O₂ Control ULPA, Moist Heat Decon, with Sealed Inner Door Kit for 170L
(4 Glass Doors With Latches), Factory Installed, 115VAC 50/60Hz
2170282 CCL-240T-9-IVF Celculture® Incubator, 240L, IR sensor, CO₂ & o₂ control ULPA, with Sealed Inner Door Kit for 240L
(4/6 Glass Doors With Latches), Factory Installed, 115VAC 50/60Hz
Accessories
Item Code Model Code Description
5170470 COA-1001 Humidity Display, Factory-installed
5170471 COA-1001-F Humidity Display, Field-installed Kit
5170472 COA-1002 CO2 Backup (Tank Switcher), Factory-installed
5170473 COA-1002-F CO2 Backup (Tank Switcher), Field-installed
5170474 COA-1004 Reversed Door Swing, Factory-installed
5170475 COA-1005 Analog Outputs, Factory-installed
5170476 COA-1005-F Analog Outputs, Field-installed
5170490 COA-1007 N2 Back-up (Tank Switcher), Factory-installed
5170491 COA-1007-F  N2 Back-up (Tank Switcher), Field-installed
5170419 COA-2018-F Roller Base (50 L)
5170478 COA-2001-F Roller Base (170 L)
5170420 COA-2019-F Roller Base (240 L)
5170421 COA-2020-F Floor Stand 200 mm (8.0”) with Adjustable Feet (50 L)
5170479 COA-2002-F Floor Stand 200 mm (8.0") with Adjustable Feet (170 L)
5170422 COA-2021-F Floor Stand 200 mm (8.0”) with Adjustable Feet (240 L)
5170423 COA-2022-F Floor Stand 700 mm (27.6")  with Casters (50 L)
5170480 COA-2003-F Floor Stand 700 mm (27.6") with Casters (170 L)
5170424 COA-2023-F Floor Stand 700 mm (27.6”) with Casters (240 L)
5170489 COA-2004-F 2-units Floor Stand Stacking Kit (For 170L)
5170999 COA-2042-F 2-units Floor Stand Stacking Kit (for 240L)
5170481 COA-2005-F 2-Stage Gas Regulator for CO₂  / N2
Choose one of the connectors below:
1080588 - CGA 320 Connector (US standard)
1080589 - BP-BS34-#8-NT4 Connector (British standard)
1080590 - G5/8-RH Connector (China standard)
5170425 COA-2024-F Extra Shelf (50 L, stainless steel)
5170327 COA-2007-F Extra Shelf (170 L, stainless steel)
5170426 COA-2025-F Extra Shelf (240 L, stainless steel)
5170483 COA-2008-F Stacking Kit (one set included with every unit purchased)
5170329 COA-2010-F Electronic CO₂ Analyzer, For CO₂ / Temp Measurement (with Temperature Probe)
5170397 COA-2016-F Electronic CO₂ + O₂ Analyzer, For CO₂ / O₂ / Temperature Measurement
5170398 COA-2017-F Electronic CO2 + O2 + RH Analyzer, For CO2 / O2 / RH /  Temperature Measurement
2170020 COA-2011-F IQ / OQ Documentation
2170021 COA-2012-F 6" Chart Recorder, Temp, 115/230 VAC, 50/60 Hz
2170022 COA-2013-F 8" Chart Recorder, Temp / Temp, 115/230 VAC, 50/60 Hz
2170023 COA-2014-F 6" Chart Recorder, Temp/RH, 115/230 VAC, 50/60 Hz
5170487 COA-2015-F Inner Door Shelving Kit for 170 L (4 sets with total 12 mini-shelves for one incubator)
5250001 Voyager® Voyager® Software Kit
1320045 MRI-GA MIRI® GA CO2 / O2 / Temp Validation Unit, 115 -230 VAC, 50/60 Hz
1250109 MRA-SS-TS SAFE Sens TrackStation for CO₂ Incubator (to be sold with 1250110). Can connect up to 8 incubators.
1250110 MRA-SS-TP SAFE Sens TrackPod for CO₂ Incubator (to be sold with 1250109)
1081277 MRA-SS-SV2 SAFE Sens SV2 Sensor, Pack of 10 pieces (shelf-life 12 months)
1081278 MRA-SS-QC2 SAFE Sens QC2 Alignment Tool

Literature & Resources